微量氧变送器EDYNE 型号:Insta Trans-XD 库号:M179081 查看hh midwest-group DESCRIPTION Two-Wire Loop-Powered Oxygen Transmitter SPECIFICATIONS • Single user-settable range, 0-10 ppm to 0-25% Oxygen • Front-facing head containing digital display and keys for convenient wall mounting • Accepts most edyne industrial sensors (Insta-trace and A-5 type cells require special configurations) • Weather-tight housing designed to meet NEMA-4 / IP-66 ingress protection requirements • 316SS cell housing with 316SS 1/8" tube fittings and Viton® o-ring as standard • Optional fittings: 1/4" tube, 6mm tube, no fitting (1/8" FNPT threads) • Optional o-rings of Kalrez®, EPDM, EPR, Neoprene, Chemraz® and Buna-n • Microprocessor-based single PCB design • 4.5 digit LCD • 4-20mA loop output • Cold boot and 4-20 fine adjust features included as standard • Intrinsically safe to ATEX Ex ia IIC T4 Ga when wired with approved barrier as per D86181 Interconnection Diagram • Intrinsically safe to FM / FMc Class I Div 1 Gp A-D T4 when wired with approved barrier as per D I8n6te1r8c1onnection Diagram and FM / FMc Class I Div 2 Gp A-D T4 without barrier (approvals pending) • Cable included, 2-conductor 22 AWG shielded, 24 inch (610 mm) length • Fuel cell included中西集团 |